Ultimate Energy Efficient KOBELCO's Flagship
By developing state-of-the-art air-ends and optimized package design, we achieved best in class specific power consumption as well as utmost durability. Here, new standard of oil-free compressors starts.
Range
With specific power consumption as our primary design criterion, we strive to deliver products that maximize energy efficiency for our customers. The integration of ultra-high-efficiency motors and optimized package design has enabled us to set a new benchmark for specific energy performance in its class.
KOBELCO’s proven dual vent holes design prevents oil entry in compressor chambers during unload running.
KOBELCO has received Class 0 certification (ISO8573-1 [-:-:0]) for〈Emeraude ALE〉series from international test institute called TÜV which certifies the highest level of purity for quality classifications of compressed air.
Long Overhaul cycle has been achieved thanks to long life cycle bearings.
Various noise control techniques has drastically reduced sound level. Making the working environment more comfortable.
Proven Teflon coating and 2nd stage’s Stainless steel rotors secure high durability against drain attack and prevent performance deterioration due to corrosion.
Cooling air inlet points have been put into one place to reduce noise.
Noise absorbing material and high sealing ability against abrasive noise reduce noise leakage.
Newly designed suction and discharge silencers reduce noise level.
Easy access to key service parts for maintenance thanks to large panels and reduction of internal piping.
Filter type and compact exhaust cleaner has over 99% of oil mist separation performance and keeps inside of unit clean. Moreover, pressure resistance doesn’t increase for long time because oil mist is separated itself.
Heat loss is small and high efficiency is kept even during low load condition.
Equipped with a 7-inch full-color touch screen controller, it allows for easy monitoring of compressor operation and various settings.
By interconnecting multiple units, max, 6 units can be automatically operated, achieving optimal energy-saving operation without group controller.
* Keep the water temperature below 40℃ for water cooled model.
* Please refer to standard specification manual for water quality.
*Please contact our sales team for more updated specification and information.
] Features
Class-leading specific power consumption
Unique design to ensure “Oil-free”
Class 0 certified
Long life cycle
Outstanding quietness
Superior Anti-corrosion performance
Package structure for noise reduction
Panel design
Silencer
New measurement standard is more stringent than previous one because of 9point average and 1m around the unit.
Easy maintenance
Exhaust cleaner without power source or instrument air
Main motor
IPM motor for Inverter model
Comparison of motor efficiency (for reference)
Comparison of structure
IE3 motor for fixed speed model
Enhancing usability with touchscreen controller
Group control (up to 6 units)
Specifications
Inverter / Water cooled model
Model
Max. Discharge Pressure
Free Air Delivery
Main motor
Discharge Connection
Dimensions
Noise Level
Voltage
Weight
50 / 60Hz
W×D×H
MPa
m3/min
cfm
kW
mm
dB(A)
kg
ALE132WVⅣ
0.75
24.8
876
132
JIS10k 65A FF
2,705 × 1,545 × 1,845
66
380・415
3,700
0.86
22.0
777
1.04
19.6
692
ALE160WVⅣ
0.75
29.3
1,035
160
3,800
0.86
26.8
946
1.04
24.8
876
ALE250WVⅣ
0.75
45.4
1,603
250
JIS10k 80A FF
3,150 ×1,600 × 2,180
5,350
0.86
41.7
1,473
1.04
38.5
1,360
Inverter / Air cooled model
Model
Max. Discharge Pressure
Free Air Delivery
Main motor
Discharge Connection
Dimensions
Noise Level
Voltage
Weight
50 / 60Hz
W×D×H
MPa
m3/min
cfm
kW
mm
dB(A)
kg
ALE132AVⅣ
0.75
24.0
848
132
JIS10k 65A FF
3,730 × 1,700 × 1,995
71
380・415
4,300
0.86
21.1
745
ALE160AVⅣ
0.75
28.3
999
160
73
4,300
0.86
25.8
911
ALE250AVⅣ
0.75
44.4
1,568
250
JIS10k 80A FF
4,300 × 1,900 × 2,180
76
5,600
0.86
40.8
1,441
Fixed speed / Water cooled model
Model
Max. Discharge Pressure
Free Air Delivery
Main motor
Discharge Connection
Dimensions
Noise Level
Weight
50Hz
W×D×H
Voltage
Star-Delta
Reactor*
MPa
m3/min
cfm
kW
mm
dB(A)
kg
ALE132WⅣ
0.75
24.8
876
132
JIS10k 65A FF
2,705 × 1,545 × 1,845
66
380・415
4,100
–
0.86
21.6
763
1.04
19.9
703
ALE145WⅣ
0.75
26.5
936
145
4,200
–
0.86
24.8
876
1.04
21.5
759
ALE160WⅣ
0.75
29.2
1,031
160
4,200
–
0.86
26.5
936
1.04
24.7
872
ALE200WⅣ
0.75
37.4
1,321
200
JIS10k 80A FF
3,150 × 1,600 × 2,180
66
380・415
5,950
–
0.86
33.7
1,190
1.04
30.3
1,070
ALE250WⅣ
0.75
45.0
1,589
250
5,950
–
0.86
41.4
1,462
1.04
38.1
1,345
ALE275WⅣ
0.75
48.6
1,716
275
6,000
–
0.86
45.0
1,589
1.04
41.3
1,458
ALE315WⅣ
0.75
54.6
1,928
315
JIS10k 100A FF
3,850 × 2,000 × 2,400
〈 4,082 × 2,000 × 2,400 〉70
380・415
9,100
–
0.86
51.5
1,819
10,000
–
10,200
1.04
48.0
1,695
–
–
–
ALE355WⅣ
0.75
63.1
2,228
355
380・415
9,150
–
0.86
58.8
2,077
10,000
–
10,300
1.04
54.5
1,925
–
–
–
ALE400WⅣ
0.75
66.8
2,359
400
75
380・415
9,400
–
0.86
63.1
2,228
10,000
–
10,450
1.04
58.7
2,073
70
–
–
–
Fixed speed / Air cooled model
Model
Max. Discharge Pressure
Free Air Delivery
Main motor
Discharge Connection
Dimensions
Noise Level
Voltage
Weight
50Hz
W×D×H
MPa
m3/min
cfm
kW
mm
dB(A)
kg
ALE132AⅣ
0.75
23.8
840
132
JIS10k 65A FF
3,730 × 1,700 × 1,995
71
380・415
4,700
0.86
20.9
738
1.04
19.2
678
ALE145AⅣ
0.75
25.6
904
145
71
4,700
0.86
23.8
840
1.04
20.7
731
ALE160AⅣ
0.75
28.2
996
160
73
4,700
0.86
25.6
904
1.04
23.8
840
ALE200AⅣ
0.75
35.4
1,250
200
JIS10k 80A FF
4,300 × 1,900 × 2,180
76
380・415
6,200
0.86
33.0
1,165
1.04
29.8
1,052
ALE250AⅣ
0.75
44.0
1,554
250
6,200
0.86
40.5
1,430
1.04
37.3
1,317
ALE275AⅣ
0.75
47.6
1,681
275
6,250
0.86
44.0
1,554
1.04
40.4
1,427
Water cooled model
Model
Cooling water Quantity
△T
Water inlet temperature
Water inlet / outlet connection
Initial lubricant charge
L / min
℃
L
ALE132WVⅣ
ALE132WⅣ238
10
20
JIS10k 50A FF
25
ALE145WⅣ
261
ALE160WVⅣ
ALE160WⅣ288
ALE200WⅣ
355
JIS10k 65A FF
30
ALE250WVⅣ
ALE250WⅣ443
ALE275WⅣ
487
ALE315WⅣ
492
JIS10k 80A FF
50
ALE355WⅣ
555
ALE400WⅣ
625
* Please refer to standard specification manual for water quality.
Air cooled model
Model
Cooling fan motor output
Initial lubricant charge
kW
L
ALE132AVⅣ
ALE132AⅣ6
(3kW×2)35
ALE145AⅣ
ALE160AVⅣ
ALE160AⅣ
ALE200AⅣ
11
(5.5kW×2)51
ALE250AVⅣ
ALE250AⅣ
ALE275AⅣ
* Suction conditions Absolute suction pressure: 0.10MPa, Suction temperature: 20℃, Humidity: 0%RH.
* Discharge air volumes is converted to suction conditions.
* Discharge pressure are measured after gas coolers.
* Air produced by compressors should not be used in respiratory equipment furnishing air for direct inhalation.
* Nominal working pressure of 0.75MPa & 0.86MPa model is 0.70MPa.
* Nominal working pressure of 1.04MPa is 0.90MPa.
* Since the cooling for the compressed air & the inside of the compressor unit depends on the surrounding air condition, the surrounding air must be properly ventilated to prevent the ambient temperature from rising above 45℃. ( For air-cooled 1.04MPa model, the surrounding air temperature should not exceed 40℃ )
* Please be sure to use the lubricating oil recommended by KOBELCO.
* Specifications and appearances are subject to change without notice Contact us if guaranteed values of performance is needed.